Water Cooled Swimming Pool Heater and Chiller

Type: Water-Cooled
Cooling Method: Direct Cooling
Unit Structure: Integral
Selected Voltage: 380V/50HZ
Compressor Number: 2
Noise Level: Ordinary
Customization:
Gold Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
DSW-350S
Application Fields
Pharmaceutical
Application Machine
Machining Center
Certification
CSA, RoHS, UR, ISO, UL, CE, CCC
Condition
New
Size(mm)
2550*900*1335~3950*1100*2100
Weight(Kg)
1080~4400
Ce
Ce, SGS, ISO9001
Water Chiller
High-Quality Water Chiller
Usage
for Manufacture
Transport Package
Standard Wooden Package
Specification
CE, ISO, SGS
Trademark
DASEN
Origin
China
HS Code
8418692090
Production Capacity
10000 Sets

Product Description

Water Cooled swimming pool heater and chiller

Ranges: Chiller, Water Chiller, Air Chiller, Air Cooled Chiller, Water Cooled Chiller, Water Cooling Chiller, Air Cooled Chiller, Heat Pump, Industrial Chiller Unit

As industrial water chiller, this water source heat pump has the following specification:

1. Cooling capacity: 165kw~920kw.

2. Cooling conditions: Chilled water inlet temperature is 12 degrees, outlet temperature is 7 degrees.

3. Input power: 3P-380V-50Hz, Allowable fluctuate voltage: ± 10%, allowable voltage difference in phase: ± 2%.

4. Temperature of chilled water should be 5 degrees~15 degrees.

5. Semi-closed 5: 6 asymmetric twin-screw compressor from world-renowned brand, trouble-free operation over 100000hours.

6. Four stages volume control or 0%-100% automatic regulation.

7. Provide thermal outlet water temperature up to 52degrees.

8. Use PLC microcomputer control from Germany Siemens LCD touch screen, both English and Chinese human-machine interface.

9. A dual-purpose machines, which provide hot water in winter as well as the provision of cold water in the summer.

10. Friendly choose to use environmentally R407C or R134A refrigerant.

11. Environmental protection and energy saving. Can make use of ground water and domestic wastewater renewable energy.
CHILLER, WATER CHILLER, WATER COOLED CHILLER
Water Cooled Swimming Pool Heater and Chiller
Water Cooled Swimming Pool Heater and Chiller
Water Cooled Swimming Pool Heater and Chiller
Water Cooled Swimming Pool Heater and Chiller
Water Cooled Swimming Pool Heater and Chiller
Water Cooled Swimming Pool Heater and Chiller

 
                     Item                          Type DSW-
1651 2001 2401 2951 3751 4101 4901 5101 5801 6201 6801 7251 8201 8901 9201
Cooling condition Cooling capacity KW 165 200 240 295 375 410 490 510 580 620 680 725 820 890 920
104Kcal/h 14.2 17.2 20.7 25.4 32.3 35.3 42.2 43.9 49.9 53.4 58.5 62.4 70.6 76.6 79.2
Input power KW 28.8 34.5 42.3 51.5 65.9 71.8 85.8 89.1 101.2 108.8 118.7 126 144.1 153.2 157.5
Rated Current A 49.8 59.7 73.2 89.1 114 124.2 148.4 154.1 175.1 188.2 205.4 218 249.3 265 272.5
Chilled water flow m3/h 28.4 34.4 41.4 50.8 64.6 70.6 84.4 87.8 99.8 106.8 117 124.8 141.2 153.2 158.4
Chilled water pressure drop Kpa 49 49 50 52 52 54 55 57 57 57 61 61 63 65 67
Well the source of water flow m3/h 14.8 17.9 21.5 26.4 33.6 36.8 43.9 45.7 52 55.6 61 65 73.5 79.8 82.5
Well the source of water pressure drop Kpa 26  26  26  28  29  29  30  31  32  34  36  37  38  40  41 
Heating condition Cooling capacity KW 175 215 260 315 405 445 530 550 625 670 755 815 950 1025 1060
104Kcal/h 15.1 18.5 22.4 27.1 34.9 38.3 45.6 47.3 53.8 57.7 65 70.1 81.8 88.2 91.2
Input power KW 39.7 47.8 58.5 71.2 91.6 99.8 119.2 123.8 140.7 151.2 165.2 175.1 200 213.4 218.9
Rated Current A 68.7 82.7 101.2 123.2 158.5 172.7 206.2 214.2 243.4 261.6 285.8 302.9 346 369.2 378.7
Chilled water flow m3/h 30.1 37 44.8 54.2 69.7 76.6 91.2 94.7 107.6 115.3 129.9 140.3 163.5 176.4 182.4
Chilled water pressure drop Kpa 47 48 48 50 52 53 55 57 59 62 65 67 69 72 74
Well the source of water flow m3/h 18.3 22.5 27.2 33 42.4 46.6 55.5 57.6 65.4 70.1 79 85.3 99.5 107.3 111
Well the source of water pressure drop Kpa 27 27 28 29 29 30 30 31 31 31 34 34 35 36 37
 Run control Use PLC microcomputer control
Power Supply 380V/3N/50Hz
Compressor Type Semi-closed 5:6 asymmetric twin-screw compressor
Amount 1
Startup type YStart
Energy regulation 0-12.5-25-37.5-50-62.5-75-87.5-100%
Evaporator Type Pipe dry high efficiency heat exchanger
Interface size DN80 DN100 DN125 DN150 DN200
Condenser Type Pipe high efficiency heat exchanger
Interface size DN80 DN100 DN125 DN150 DN200
Refrigerants Type R22
Refrigerant volume kg 45 55 67 81 104 114 136 141 160 171 193 209 243 262 271
Overall dimensions Length mm 2550 2600 2870 2860 2860 2920 3220 3320 3550 3550 3650 3700 3850 3950 3950
Width mm 900 900 900 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100
Height mm 1335 1430 1430 1540 1770 1770 1780 1780 1910 1910 1950 2100 2100 2100 2100
Machine weight Kg 1080 1300 1370 1680 1800 2130 2380 2660 2950 3010 3210 3460 4170 4390 4490
Operating weight Kg 1180 1450 1570 1940 2100 2390 2640 2980 3120 3330 3570 3880 4600 4780 4940
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now